bioVibez LX-AC-R2A-D – Ambient light / LUX sensor automatic switch is a dual output / channel micro-controlled dusk to dawn sensor with user configurable relay output. The sensor’s parameters can be configured using a touch switch and two 7-segment LED display to navigate its menu. Channel parameters can be set independently. Also, channel can be disabled if LUX para is ‘OFF’.
Microcontroller based - A microcontroller-based design gives more precise digital control.
Discrete LUX set points (16-presets) -
Parameters - L1 & L2
Set point values - OFF, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 120, 140, 150, 170, 200
Start delay control (16-presets) - Output switch ‘ON’ time delay, once set point is reached.
Parameters - d1 & d2
Values - 0FF, 5, 10, 20, 30, 40, 50 in sec, & 1, 2,5, 10, 15, 20,30, 45, 60 in minutes.
Shutdown period control (12-presets) - turns ‘OFF’ relay after set time
Parameters - P1 & P2
Values - 0FF, 30 min. & 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 in hours.
Channel output test (‘ON’/’OFF’) - switches output ‘ON’ / ‘OFF’ for testing
Parameters - o1 & o2
Values - 0FF & ON
SMPS - for standby power savings. The module is powered by a built in universal SMPS (switched mode power supply).
Dynamic set lux point - Dynamic set point is captured after a delay, once channel relay switches ‘ON’. The dynamic set point includes the new ambient lux value of the light attached to the outputs. This prevents hunting or race condition.